Pytanie |
Odpowiedź |
Single storey dwelling (4 bed 6 person = 99sq.m) Two storey dwelling (4 bed 6 person = 107sq.m) Three storey dwelling (4 bed 6 person = 113sq.m) rozpocznij naukę
|
|
Standardy Mieszkaniowych standartów
|
|
|
For dwellings designed for more than 6 people, at least 10sq.m. gross internal area should be provided for each additional person. rozpocznij naukę
|
|
Powierzchnia wewnętrzna brutto
|
|
|
Dwelling plans should demonstrate that dwellings will accommodate the furniture, access and activity space requirements relating to the declared level of occupancy. rozpocznij naukę
|
|
|
|
|
The minimum width of hallways and other circulation spaces inside the home should be 900mm. This may reduce to 750mm rozpocznij naukę
|
|
|
|
|
Minimum clear opening width of doorway (mm) = 750 rozpocznij naukę
|
|
|
|
|
Living / dining / kitchen The following combined floor areas for living / kitchen / dining space should be met: 2 person = 23sq.m. 3 person = 25sq.m. 4 person= 27sq.m. 5 person= 29sq.m. 6 person= 31sq.m. rozpocznij naukę
|
|
Salon / jadalnia / kuchnia
|
|
|
Designed level of occupancy rozpocznij naukę
|
|
|
|
|
The minimum width of the main sitting area should be 2.8m in 2-3 person dwellings and 3.2m in dwellings designed for four or more people. rozpocznij naukę
|
|
|
|
|
Dwellings with three or more bedrooms should have two living spaces, for example a living room and a kitchen-dining room. Both rooms should have external windows. rozpocznij naukę
|
|
|
|
|
Both rooms should have external windows. If a kitchen is adjacent to the living room, the internal partition between the rooms should not be load-bearing, to allow for reconfiguration as an open plan arrangement. rozpocznij naukę
|
|
|
|
|
rozpocznij naukę
|
|
|
|
|
the internal partition between the rooms should not be load-bearing, to allow for reconfiguration as an open plan arrangement. rozpocznij naukę
|
|
|
|
|
There should be space for turning a wheelchair in dining areas and living rooms and basic circulation space for wheelchairs elsewhere rozpocznij naukę
|
|
|
|
|
A living room, living space or kitchen dining room should be at entrance level rozpocznij naukę
|
|
|
|
|
The minimum area of a single bedroom should be 8 sq m. The minimum area of a double or twin bedroom should be 12 sq m. rozpocznij naukę
|
|
|
|
|
The minimum width of double and twin bedrooms should be 2.75m in most of the length of the room. rozpocznij naukę
|
|
|
|
|
convenient temporary bed space In homes of two or more storeys with no permanent bedroom at entrance level=, there should be space on the entrance level that could be used as a convenient temporary bed space rozpocznij naukę
|
|
wygodna tymczasowa sypialnia
|
|
|
Structure above a main bedroom and an accessible bathroom should be capable of supporting a ceiling hoist and the design should allow for a reasonable route between this bedroom and bathroom rozpocznij naukę
|
|
|
|
|
rozpocznij naukę
|
|
|
|
|
Dwellings designed for an occupancy of five or more people should provide a minimum of one bathroom with WC and one additional WC. rozpocznij naukę
|
|
|
|
|
Where there is no accessible bathroom at entrance level=, a wheelchair accessible WC with potential for a shower to be installed should be provided at entrance level rozpocznij naukę
|
|
|
|
|
A minimum of 5 sq m of private outdoor space should be provided for 1-2 person dwellings and an extra 1 sq m should be provided for each additional occupant. rozpocznij naukę
|
|
Prywatna otwarta przestrzeń
|
|
|
The minimum depth and width of all balconies and other private external spaces is 1500mm. rozpocznij naukę
|
|
|
|
|
the designer should demonstrate how good levels of ventilation, daylight and privacy will be achieved in each habitable room and the kitchen. rozpocznij naukę
|
|
|
|
|
The minimum floor to ceiling height in habitable rooms is 2.5m between finished floor level and finished ceiling level. rozpocznij naukę
|
|
Wysokość od podłogi do sufitu
|
|
|
A minimum floor to ceiling height of 2.6m in habitable rooms is considered desirable rozpocznij naukę
|
|
|
|
|
encouraged to do something taller ceiling heights are encouraged in ground floor dwellings. rozpocznij naukę
|
|
zachęca do zrobienia czegoś
|
|
|
Glazing to all habitable rooms should be not less than 20% of the internal floor area of the room. rozpocznij naukę
|
|
|
|
|
stair providing easy access In the Lifetime Homes Criteria a stair providing easy access is defined as one having maximum risers of 170mm, minimum goings of 250mm and a minimum width of 900mm measured 450mm above the pitch line. rozpocznij naukę
|
|
schody zapewnia łatwy dostęp
|
|
|
double loaded (they serve dwellings on each side) rozpocznij naukę
|
|
|
|
|
All main entrances to houses, ground floor flats and communal entrance lobbies should be visible from the public realm and clearly identified. rozpocznij naukę
|
|
|
|
|
communal entrance lobbies rozpocznij naukę
|
|
|
|
|
All main entrances to houses, ground floor flats and communal entrance lobbies should be visible from the public realm and clearly identified. rozpocznij naukę
|
|
|
|
|
The approach to all entrances should preferably be level or gently sloping rozpocznij naukę
|
|
|
|
|
The approach to all entrances should preferably be level or gently sloping rozpocznij naukę
|
|
|
|
|
All entrances should be illuminated and, have level access over the threshold rozpocznij naukę
|
|
|
|
|
All entrances should be illuminated and, have level access over the threshold rozpocznij naukę
|
|
|
|
|
Entrance doors should have 300mm of clear space to the pull side, and clear minimum opening widths of 800mm or 825mm depending on the direction and width of approach. rozpocznij naukę
|
|
|
|
|
Entrance doors should have 300mm of clear space to the pull side, and clear minimum opening widths of 800mm or 825mm depending on the direction and width of approach rozpocznij naukę
|
|
|
|
|
Main entrances should have weather protection and a level external landing. rozpocznij naukę
|
|
|
|
|
rozpocznij naukę
|
|
|
|
|
Summary of evidence on proposed housing design standards for the Examination in Public of the draft replacement London Plan rozpocznij naukę
|
|
|
|
|